Kay & Company
Home About Kay & Company Our Products Our Certifications Send Enquiry Site Map Contact us  
PRODUCT RANGE

Our Certifications

Kay & Company
is an ISO 9001-200 certified organization. We are first Indian company to get the prestigious ISO 13485 certification for medical devices. Several of our product categories have the coveted CE certification. This further re-enforces the confidence of importers and end users to indent for our products. Purchasing executives directly connected with the health care industry are welcome to contact us directly. Our proximity to the Indian dry ports gives us the advantage of competitive pricing and delivery schedules. For direct importers this gives us the benefit of shipping out "less than container load" shipments. read more

Nursery Equipment

Kay & Company offers a wide range of world-class, CE marked Nursery Equipment. The range caters to all specialties, including Infant Incubator-Neonatal Intensive Care Incubator.

     1   2   3   4   Next »

INFANT INCUBATOR - Neonatal Intensive Care Incubator

Neonatal Intensive Care Incubator
Model: 100A

Specification:

Working temperature range

Accuracy
Resolution
Accuracy of probe Interchangeability
Need for probe calibration
Temperature Probe
Voltage
Power
Heating element
Temperature display
Message and alarms

: 32° to 38° C (patient mode)
: 30° to 38° C (Air mode)
: +/- 0.2° C
: 0.1° C
: +/- 0.2° C
: Not required
: Thermistor based interchangeable probe
: 220 to 250V at 50 Hz
: 500 Watts
: Encapsulated heater with aluminum fins.
: Bright Numerical LED display
: Alphanumerical display

Performance Specifications:

Temperature rise time
Temperature variability
Temperature overshoot
Bed tilting position

: 20-30 min per 10° C
: 0.2° C
: 0.8° C
: + 8° C maximum continuously variable on both sides

Oxygen Concentration:

Oxygen input
5 litres min-1
10 litres min-1
15 litres min-1
Humidification (Optional)
Range
Display resolution

Average concentration range
: 25 to 45%
: 35 to 60%
: 45 to 70%
: Using controller
: 40-90 + 5%
: + 5%

Audio and visual display alarm conditions:
* Patient temperature (more than + 0.5° C difference) * Control temperature
* High Air temperature (more than + 0.5° C difference) * Circular fan failure
* Probe failure * System failure * Power failure * Heater failure
(Automatic heater cutoff if the temperature inside the incubator exceeds 40° C)

Coating :
Epoxy/powder coated body for scratch and rust prevention

Dimension (maximum)

Incubator canopy
Length
Width
Heigth
Mattress
Casters


: 820 mm
: 470 mm
: 430 mm
: 650 mm
: 125mm diameter, 2 locking and 2 non-locking

Operational environment:


Operating temperature range
Storage temperature range
Operating humidity range

: 20° C to 32° C
: -25° C to 60° C
: zero to 95%

* Confirms IEC-601 safety standard for medical equipment.
* Microprocessor based electronic system that performs periodical self-diagnosis.
* Easy to operate membrance keypad for better user efficiency.
* Easy to clean air circulation path helps to maintain high level of hygiene.
* Mobile with 4 swivel castors.
    Kay & ComapnySend Enquiry

     1   2   3   4   Next »

OTHER PRODUCTS IN THIS CATeGORY
- Neonatal Intensive Care Incubator
- Neonatal Phototherapy Unit
- Neonatal Radiant Warmer
- Open Care Warmer - Resuscitation Unit
- Transport Incubator
other product range
- Hospital Furniture
- Nursery Equipment
- Operation & Examination Lamp
- Suction Units/Vacuum Extractors
- Resuscitators/Anaesthesia Mask
- Laryngoscopes
- Sphygmomanometers
- Dignostic Instruments
- Hospital Hollowwares
- Scales
- Pressure Stoves/Lanterns
- Autoclave Portable
- Hot Air Sterilizers
- Water Bath
- Centrifuge
- Laboratory Incubator
- Vaginal Speculms
- Hospital Rubber Products
- Kit Boxes/General Items
- Medical Disposables
- Electro Surgical Units

Home    |    About Kay & Company    |    Our Products    |    Our Certifications    |    Send Enquiry    |    Site Map    |   Contact
Copyright © Kay & Company. All Rights Reserved